Full metadata record
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineeringen_US
dc.contributor.advisorWong, Ling Tim (BSE)en_US
dc.creatorLai, Chung Nok-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/11253-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic Universityen_US
dc.rightsAll rights reserveden_US
dc.titleCharacterize long term CO₂ concentrations in an office environment (data analysis & computational work)en_US
dcterms.abstractIndoor Air Quality has drawn more attention in the society, and global CO2 problem has become extremely series. The indoor CO2 concentration level has been pointed out that several problems are derived from this air parameter. Health problem and working performance are the two predominant benefits gained from dealing with high CO2 concentration in a indoor environment. In view of this, computational analysis seems to be necessary when it comes to enhance the performance of a HVAC system. There are many parameters potentially included in time series modelling, however, sorely CO2 concentration changes over time in the office are covered as the parameter. Box-Jenkins methodology has been adopted as the time series analysis, in which an iterative three stages modelling is involved. Model identification, parameter estimation and statistical model checking are employed so as to conduct corresponding tests on stationarity, seasonality, best fit coefficients for ARIMA, and the stationary univariate. Further explaining the modelling approach, a number of tests have been carried out prior to ARIMA modelling. Identifying the parameters by comparing the ACF and PACF plots, stationarity tests by ADF test, Q-Q plots are examples that ensure the assumption behind the ANOVA tests and the modelling premises. To minimize the work size, locations 4,11,14 are chosen as the most representative locations under comparison in ANOVA tests. The corresponding relationship of 17 locations are in comparison according to the statistical significance. In order to study the data adequacy, using longer time intervals are also one of the objectives to be achieved. Data ranging from 1 to 3 weeks has been employed and computed for residual analysis such that the impact of time duration can be clearly observed. Since the work is confined by several limitations, there are more computational work and further research expected to be conducted as follow-up work after this research. It is ideally anticipated that electricity consumption will be covered or other environmental impacts could be interpreted from the study of time series models.en_US
dcterms.extent67 pages : color illustrationsen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2021en_US
dcterms.educationalLevelM.Eng.en_US
dcterms.educationalLevelAll Masteren_US
dcterms.LCSHIndoor air qualityen_US
dcterms.LCSHCarbon dioxide -- Environmental aspectsen_US
dcterms.LCSHAir conditioningen_US
dcterms.LCSHIndoor air pollutionen_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
5729.pdfFor All Users (off-campus access for PolyU Staff & Students only)2.03 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/11253