dc.titleConvergence problems in fast decoupled load flow type methodsen_US
dcterms.abstractThe FDLF type methods developed by Stott and Alsac have been widely used in power system load flow studies to expedite the speed of computation. However, under certain conditions, FDLF does have convergence difficulties. In the dissertation, the convergence condition for the general non-linear iteration scheme is first determined and this is applied to the FDLF to get the theoretical convergence criteria. The convergence of FDLF is shown to be dependent on the network parameters (the maximum R/X ratio, the susceptances) and the region of interest for the solution. To overcome the convergence problem, several approaches have been suggested, namely: 1. The series compensation scheme by Dy Liacco and Ramarao, 2. The parallel compensation scheme by Deckmann et al, 3. The MFDLF by Fang, Song and Chung, 4. The reverse Stott model by Nanda et al, 5. Rajicic and Bose's Method, and 6. Super decoupled load flow with distributed slack bus by Haley and Ayres. The various methods have been surveyed, this is followed by critical evaluation and comparison of the efficiency and effectiveness of them. None of the methods seems to offer a perfect solution. The FDLF and MFDLF have been successfully implemented on a personal computer, using the standardised FORTRAN language, and applied to a 5 bus sample and the IEEE 14 bus. No computer storage problem was encountered, acceptable accuracy was achieved, and the time of execution was generally within seconds. Only a modest amount of modifications on the FDLF program is necessary to accomplish the MFDLF. The MFDLF method has been further amended here with the following novel features: a. Use the mean argument of Yii's as the angle of rotation, b. Employ a multiplier p, which is empirically determined, to the angle of rotation, c. Adjustment of the P vector for PV buses. The amendments will enhance convergence, preserve the symmetry of the [Y] matrix, simplify calculations and improve accuracy.en_US
dcterms.extent1 v. (various pagings) : ill. ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued1995en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Sc.en_US
dcterms.LCSHElectric power systems -- Load dispatchingen_US
dcterms.LCSHConvergenceen_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b12050416.pdfFor All Users (off-campus access for PolyU Staff & Students only)3.79 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/3099