dc.titleSurvey of the indoor air quality at schoolsen_US
dcterms.abstractTwo different types of ventilation system are commonly adopted in the schools: i) window A/C units plus mechanical exhaust (and supply) fans and ii) natural ventilation supplemented by ventilation fans. There was not much research work conducted in school premises around the territory. Besides, after implementation of the Noise Control Ordinance, many new and existing schools have installed air-conditioning system. According to information from the Education Department, the Department has already arranged to install air-conditioning equipment in approximately 5,400 classrooms to alleviate the noise problem. It is beneficiary and worthwhile to investigate the indoor air quality at schools so as to sort out any possible health risk to the building occupants, especially the children. On the other hand, government or subvented schools constructed by either the Architectural Services Department (ASD) or the Housing Department (HD) are more or less similar, both in the building appearance and the services installed. The mechanical ventilation system design will be discussed in Chapter 8. Besides, the IAQ records taken from these schools can be set up as a database for future reference. The main objectives of this research project are 1) to investigate the effect of the type of ventilation on the air quality inside classrooms, particularly the carbon dioxide concentration, temperature and relative humidity. 2) to apply the statistical software - Statistical Package for the Social Sciences (SPSS) and verify for any possible correlation between indoor air parameters and students' reported symptoms inside classrooms. 3) to study the Year 2000 version standard primary and secondary schools ventilation system design. Twenty schools strategically selected around the territory; including both primary and secondary schools were approached to conduct the indoor air quality survey. Subsequently, eleven schools granted permission. Considering the need of continuous measurement and to minimize disturbance to the class activities, automatic data loggers were used to provide real time monitoring and in-depth study of carbon dioxide concentration, temperature and relative humidity in the classrooms. The indoor air quality data collected at the schools are analysed. Results indicated that the capacities of window A/C units at the air-conditioned classrooms were insufficient to extract the moisture generated from breathing. Besides, the ventilation rates of exhaust (and air intake) fans at most air-conditioned schools were below ASHRAE's recommendations. According to the measured carbon dioxide concentrations at the natural ventilated schools, the ventilation rates were generally in order. However, the temperature and humidity at the classrooms were either close to the boundary or out of the comfort zone as defined in ASHRAE Standard 55-1981, especially during the summer season. Apart from the physical measured data, information from questionnaires returned by the students have been tested with the Statistical Package for the Social Sciences (SPSS) programme. The students' subjective evaluation of the indoor air quality and environmental parameters are found to be generally in-line with the indoor climatologic measurements. Finally, an overview of existing schools' ventilation design and recommendations on the possible improvements are given in Chapter 8. Moreover, an introduction to the Year 2000 version standard primary and secondary schools has been included as part of the research work.en_US
dcterms.extentxv, 57, [438] leaves : ill. (some col.), col. maps ; 31 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued1999en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Sc.en_US
dcterms.LCSHSchools -- China -- Hong Kong -- Environmental aspectsen_US
dcterms.LCSHAir quality -- China -- Hong Kongen_US
dcterms.LCSHIndoor air pollution -- China -- Hong Kong -- Measurementen_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b14852469.pdfFor All Users (off-campus access for PolyU Staff & Students only)31.15 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/3715