dc.titlePerformances of the a new thermal storage material combined with chilled-ceiling systemen_US
dcterms.abstractThe electricity charge in daytime is much higher than that in nighttime. A prevalent method which uses the electricity for to store cooling in a phase change material in nighttime can save a lot of money because the nighttime tariff is much cheaper than that in daytime in many places. This dissertation is aimed to assess the performances of a new thermal storage materials combined with a radiant ceiling cooling system. Four main groups of experiments and tests were conducted in order to achieve the objectives. The results of heat balance measurement indicate that the errors between thermal energy supply and thermal were all less than 5%. Most of the errors are less than 1%. Three significant findings are obtained from the current study. The first is that the latent heat of the C16H34 which was detected by the Differential Scanning Calorimeter (DSC) was almost the same with that of assessed by the practical running in the hybrid system. This phenomena proves that the DSC result is dependable. The second is that the change trend of convective heat transfer coefficient needs to be divided into two phases. The last one is that a pattern has been found which is used for expressing the relationship between the stir velocity and the convective heat transfer coefficient of this MPCM. The results from this dissertation are useful for users to find a suitable stir velocity for this kind of MPCM slurry to achieve the best thermal performance in practical applications. The damage to the MPCM particles which is caused by the stir should be further investigated.en_US
dcterms.alternativePerformances of a new thermal storage material combined with chilled-ceiling system for cooling-
dcterms.extentxiv, 79 leaves : ill. (some col.) ; 30 cm.en_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2008en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Eng.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertations.en_US
dcterms.LCSHHeat storage.en_US
dcterms.LCSHCooling towers.en_US
dcterms.LCSHEnergy consumption.en_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b22319955.pdfFor All Users (off-campus access for PolyU Staff & Students only)4.9 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/4080