dc.titleA study of ventilation performance and indoor particle levels in church environment in Hong Kongen_US
dcterms.abstractHong Kong is one of the most densely populated cities in the world. Land is scarce in Hong Kong, and must be used wisely. Most of churches are constructed in commercial and residential buildings, where hundreds of worshipers have their activities in limited space. The ventilation performances in the church are affected, because of limitation of design guideline and lack of professional opinions and knowledge in Hong Kong. The aim of this study is to investigate of ventilation performance and indoor air particles in environment of churches in Hong Kong. The study was divided into two sections, which involved measurements on indoor air pollutants concentration and a questionnaire survey. Respirable suspended particulates (RSP) was measured by TSI Dust Trak model 8520 monitors and CO2 concentration was measured by Telaire 7001 during 24 hours on Saturday and Sunday. Particulate matters smaller than 2.5 microns (PM2.5) are able to travel deeply into the respiratory tract, reaching the lungs. The measurement of carbon dioxide in an occupied space is an indication of the adequacy of fresh air ventilation. Therefore, this study considers two indoor parameters: PM2.5 and carbon dioxide. The results show that CO2 concentration and particulate levels of churches located in commercial and residential buildings were in excess of Guidance Notes for the Management of Indoor Air Quality in Offices and Public Places and National Ambient Air Quality Standard. Therefore, ventilation performance and indoor air particles in churches located in commercial and residential buildings were unsatisfactory because of inadequate fresh air. On the contrary, traditional standalone church has good and healthy indoor air quality because CO2 concentration and particulate levels can fulfill the requirement of those guideline and standard.en_US
dcterms.extentxiii, 144, 10 leaves : ill. ; 30 cm.en_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2009en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Eng.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertations.en_US
dcterms.LCSHChurch buildings -- China -- Hong Kong -- Heating and ventilationen_US
dcterms.LCSHChurch buildings -- China -- Hong Kong -- Environmental aspects.en_US
dcterms.LCSHIndoor air quality -- China -- Hong Kong.en_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b2303466x.pdfFor All Users (off-campus access for PolyU Staff & Students only)7.71 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/4533