dc.titlePerformance evaluation of a VAV system using air flow rate signal to control the variable-speed supply air fanen_US
dcterms.abstractA field experimental study on the performance of a VAV system having a variable speed drive for fan motor under reduced static pressure control has been carried out in two adjacent floors of an office building. Field retrofit for the VAV air conditioning system from constant static pressure control to reduced static pressure control was performed. Direct-digital-control VAV boxes and network communication technology were applied in the project. The supply fan speed was adjusted to its lowest possible level using summation of air flow passing through each VAV box as the control signal. Experimental tests were carried out to evaluate the operational performance and fan energy saving of the VAV system under reduced static pressure control algorithms as compared to the traditional constant static pressure control. The experimental results confirmed that additional fan energy saving can be achieved if duct static pressure is allowed to be further lowered as compared to constant static pressure control algorithms. The results also indicated that greater saving in fan energy consumption is achieved when a VAV system is operated in lighter load condition under reduced static pressure control algorithms. Simple payback calculation using the results from this project suggested that adopting the reduced static pressure control in VAV air conditioning systems will make the total life cycle cost much lower. The results are expected to find wide application for local air conditioned buildings.en_US
dcterms.extentvi, 131 leaves : ill. ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued1996en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Sc.en_US
dcterms.LCSHVariable air volume systems (Air conditioning)en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b12197920.pdfFor All Users (off-campus access for PolyU Staff & Students only)3.94 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/4952