dc.titleThe evaluation of energy performance of atrium space with daylight-linked lighting controlen_US
dcterms.abstractThe current design trend for commercial buildings in Hong Kong is to introduce the shopping arcade at the lower floors and provide the atrium with daylight. If daylight is properly utilized, electrical lighting energy can be saved. But the atrium could admit solar radiation into the space and increase the cooling load. What would be the overall energy performance of an atrium space with daylight-linked lighting control? Could the saving on electrical lighting power compensate the additional energy expenditure on cooling? This study was carried out for three different types of atria assuming daylight-linked lighting control was employed. The energy performance of the atria was analyzed using computer simulation programs Ecotect and HTB2. The field-measurement of average daylight factor was conducted on the real atrium site to validate the simulation results. Different daylight-linked lighting controls, fenestration glazing types, as well as skylight area were investigated. The results showed that daylight availability and space cooling load of the atrium would be greatly affected by the surrounding buildings. Glazing and skylight of an atrium play a vital role on the daylight availability and air-conditioning energy consumption. Both glazing type and skylight area have great influence on the average daylight factor of the atrium. Glazing type of atrium, however, has more significant effect of cooling load control than atria skylight area. The results also indicated that atrium building of high daylight availability would consume more energy per annum. The daylight-linked lighting controls can provide an annual lighting energy saving over of 75% (compared with no lighting control). This energy saving from electrical lighting can compensate the induced energy consumption. With regard to the overall energy performance, the introduction of atrium can be energy beneficial.en_US
dcterms.extentv, 99 leaves : ill. ; 30 cm.en_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2006en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Eng.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.LCSHAtrium buildings -- China -- Hong Kong -- Lightingen_US
dcterms.LCSHDaylighting -- Evaluationen_US
dcterms.LCSHElectric lighting -- Controlen_US
dcterms.LCSHLighting, Architectural and decorativeen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b19736587.pdfFor All Users (off-campus access for PolyU Staff & Students only)5.65 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/5527