Full metadata record
DC FieldValueLanguage
dc.contributorDepartment of Applied Biology and Chemical Technologyen_US
dc.creatorPang, Hei-leung-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/1047-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic University-
dc.rightsAll rights reserveden_US
dc.titleDevelopment of microplate-based biosensors for high-throughput measurementsen_US
dcterms.abstractNowadays, the increasing number of samples in environmental analysis, biomedical studies and drug screening requires the chemists to analyse a large number of samples within a short time without raising the cost of analysis of each sample. The standard microtiter plate (or microplate) is a 96-well container with small operating volume (total volume: 360ul for each well) and the flat clear bottom is suitable for optical measurement. The microtiter plate is a convenient platform to be modified as high-throughput biosensors for small sample analysis. In this project, microplate-based biosensors for dissolved oxygen measurement, toxicity tests, biochemical oxygen demand (BOD) determination and carbohydrate-protein interaction studies have been developed. ORMOSIL (organically modified silicate) optical oxygen sensors on microtiter plates have been developed via a simple, convenient and low-cost method. The ORMOSIL high-throughput oxygen sensors prepared from tetramethoxysilane (TMOS) and dimethoxy dimethylsilane (DiMe-DMOS) with tris(4,7-diphenyl-l,10-phenanthroline)ruthenium(II), [Ru(dpp)3]2+, as the sensing dye were coated onto the well bottom surface of a 96-well polystyrene microtiter plate to give a high-throughput system for dissolved oxygen measurement. The ORMOSIL high-throughput oxygen sensors adhere on the well bottom surface strongly and give linear Stern-Volmer calibration plots with high sensitivity and long term stability. The applicability of this ORMOSIL high-throughput oxygen sensor platform for cell-based toxicity assays has been studied. The toxicity of two antimalarial drugs chloroquine and quinacrine on a yeast model {Saccharomyces cerevisiae) for studying drug resistance was evaluated by measuring their effect on the respiration rate (dissolved oxygen consumption rate) of yeasts which was monitored by the ORMOSIL oxygen sensor. The ICso values (concentration of a drug that exhibits 50% respiration inhibition) of the drugs obtained by ORMOSIL oxygen sensor were found to be in good agreement with those determined by conventional optical density (OD595) method. In addition, ORMOSIL high-throughput oxygen sensors in combination with aerobic assimilatory microorganisms can also serve as biosensors for BOD determination. The BOD biosensor was constructed by coating a microbial film on top of the ORMOSIL oxygen sensing film. The microbial film was fabricated by immobilizing a bacterial species, Stenotrophomonas maltophilia, in sol-gel-poly(vinyl alcohol) matrix. The results obtained with the BOD biosensor were in agreement with those of the conventional BODs method for different wastewater samples. A simple, convenient, low-cost and high-throughput microplate-based carbohydrate sensor has been constructed for carbohydrate-protein interaction study. The high-throughput carbohydrate sensor was constructed by covalent immobilization of aminated carbohydrate onto TESPI-ORMOSIL film (TESPI = 3-(triethoxysilyl)propyl isocyanate) on a microtiter plate. The TESPI-ORMOSIL film was prepared by coating a layer of 3-(triethoxysilyl)propyl isocyanate (TESPI) onto a transparent ORMOSIL film. The application of the high-throughput carbohydrate sensors in studying carbohydrate-protein interaction has been demonstrated by the well established carbohydrate-lectin system. The results show that this microplate-based carbohydrate microarray sensor is practical for high-throughput analysis of carbohydrate-protein interactions.en_US
dcterms.extentxv, 229 leaves : ill. (some col.) ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2006en_US
dcterms.educationalLevelAll Doctorateen_US
dcterms.educationalLevelPh.D.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.LCSHBiosensorsen_US
dcterms.LCSHMicroplatesen_US
dcterms.LCSHMolecular cloningen_US
dcterms.accessRightsopen accessen_US

Files in This Item:
File Description SizeFormat 
b20592954.pdfFor All Users2.34 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/1047