dc.title | Performance analysis and optimization for retro-commissioning : a case study on the chiller plant of a university building | en_US |
dcterms.abstract | In this research, the air-conditioning system performance of the university's building is analyzed and optimized with the chiller sequencing control optimization for energy efficacy improvement. The analysis and optimization focus on the aged campus building and their inefficiency air-conditioning system to identify the energy saving opportunity. The aim of this research focuses on energy saving through the low-cost optimization on the air-conditioning system. The main purpose of this research was to identify the energy saving opportunity of the air-conditioning system for a retro-commissioning process in the existing building. The case study shows how energy saving opportunity of the building has been identified. The possible solution is discussed for increasing the air-conditioning system efficiency and achieving energy saving without major equipment changing. During the calculation of the case study, the energy saving opportunity of aged building in Hong Kong university was identified. According to the record of Facility Management Office (FMO) of university, the chiller plant has been upgraded since 2009, new water-cooled chillers have been replaced for increasing the energy efficacy of the air-conditioning system. However, the replacement work costs a high price to install the new chillers. Moreover, the energy efficacy performance of the air-conditioning system will decrease annually due to the aging equipment. In order to improve the system efficacy, this study will analyze the energy consumption of previous annual air-conditioning system performance in the university's building to find out the possible solution for the system performance optimization. After analysis on the air-conditioning system performance, the calculation of the estimated annual energy saving of the proposed chiller sequencing control strategy is reported step by step in this report. | en_US |
dcterms.extent | vi, 61 pages : color illustrations | en_US |
dcterms.isPartOf | PolyU Electronic Theses | en_US |
dcterms.issued | 2019 | en_US |
dcterms.educationalLevel | M.Eng. | en_US |
dcterms.educationalLevel | All Master | en_US |
dcterms.LCSH | Hong Kong Polytechnic University -- Dissertations | en_US |
dcterms.LCSH | Air conditioning | en_US |
dcterms.LCSH | Buildings -- Energy conservation | en_US |
dcterms.accessRights | restricted access | en_US |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
991022370854003411.pdf | For All Users (off-campus access for PolyU Staff & Students only) | 914.26 kB | Adobe PDF | View/Open |
Copyright Undertaking
As a bona fide Library user, I declare that:
- I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
- I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
- I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.
By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.
Please use this identifier to cite or link to this item:
https://theses.lib.polyu.edu.hk/handle/200/10364