dc.titleThe effects of a hinge-post-strap type functional knee brace on patients with anterior cruciate ligament reconstructionen_US
dcterms.abstractThis study compared the performance in isokinetic tests, static knee joint angle repositioning, running and jumping of subjects with ACL reconstruction under three conditions: (1) no brace, (2) functional Donjoy Legend brace, and (3) mechanical placebo knee brace. The mechanical placebo brace was made with similar materials and design as the functional knee brace except the mechanical hinges were removed. Furthermore, questions were asked using the subjective part of the Cincinnati rating scale and a custom designed questionnaire on the bracing habits and feelings towards using a functional knee brace. Thirty-one subjects with ACL reconstruction using the semitendinosus autograft, performed at least five months earlier, were recruited. Results showed that subjects ran and turned faster in the no brace condition than both bracing conditions (p<0.05). There was no significant difference in the jumping and isokinetic tests among the three conditions (p#62;0.05). For the knee joint angle repositioning test, subjects performed better in both bracing conditions than the no brace condition (p<0.05), but there was no difference between the two bracing conditions. These results suggested that the functional knee brace did not improve the motor performance of people with ACL reconstruction, after 5 months of operation. The use of a knee brace had actually caused a decline in the running and turning performance of these subjects. The only improvement observed with the brace was the static knee joint angle repositioning sense, but the improvement was not due to the mechanical hinges of the brace. It could be the cutaneous sensory stimulation from the brace that led to the improvement. Based on the above findings, the notion of functional ACL brace enhancing knee function after at least 5 months post-operation was not supported. The use of knee braces for subjects with ACL reconstruction needs further justification. For the subjective data, all subjects scored 60 points or more out of 100 in the Cincinnati subjective rating questionnaire. These results indicated that the subjects had rehabilitated quite well at the time of testing. Twenty-nine subjects(93.6%) felt that the functional knee brace could provide a sense of stability after ACL reconstruction. In conclusion, the present study has provided new information on the effects of functional knee brace on subjects with ACL reconstruction. The functional knee brace has a role to provide psychological support as well as static knee joint sense to subjects with ACL reconstruction. It could not improve the neuromuscular, running and jumping performances as evaluated in the present study, and it could even slow down the running and turning speed of these subjects.en_US
dcterms.extentxi, 128 leaves : ill. (some col.) ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2001en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Phil.en_US
dcterms.LCSHAnterior cruciate ligament -- Wounds and injuries -- Physical therapyen_US
dcterms.LCSHAnterior cruciate ligament -- Wounds and injuries -- Patients -- Rehabilitationen_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsopen accessen_US

Files in This Item:
File Description SizeFormat 
b15511959.pdfFor All Users6.58 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/123