Full metadata record
DC FieldValueLanguage
dc.contributorDepartment of Electrical and Electronic Engineeringen_US
dc.contributor.advisorYu, Changyuan (EEE)en_US
dc.creatorWang, Xujie-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/13911-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic Universityen_US
dc.rightsAll rights reserveden_US
dc.titleIon imprinted polymer utilized fiber optic Mach-Zehnder interferometer based cadmium sensorsen_US
dcterms.abstractFiber-optic Mach-Zehnder interferometers (MZIs) are widely recognized for their high sensitivity, strong anti-interference capability, compact design, and ease of fabrication. The merits make them highly attractive in various research and application fields as well. Meanwhile, cadmium ion (Cd²⁺) is a type of heavy metal ion which poses severe threats to the environment, human health, and ecosystems. Therefore, developing efficient and rapid detection methods for trace-level Cd²⁺ inspection is crucial for regulating its emission and implementing preventive measures. In this dissertation, MZI-based fiber optic sensors with two different coating approaches are demonstrated for cadmium ion monitoring.en_US
dcterms.abstractWe have designed an inexpensive, compact and reliable single-mode fiber/ multimode fiber/ no-core fiber/ single-mode fiber (SMNS) interference structure to realize highly sensitive refractive index (RI) detection for later Cd²⁺ detection after achieving functional coating. The setup includes a short section of both multimode fiber (MMF) and no-core fiber (NCF) spliced in between two single-mode fibers (SMFs), the optimal lengths of 25mm NCF and 25 mm MMF are successively determined according to the interference spectrum, main cladding modes and optical field distribution of interferometers based on single-mode fiber/ multimode fiber/ no-core fiber/ single-mode fiber (SNS) and SMNS, respectively. The fabricated sensors offer an average linear RI sensitivity of over 190 nm/RIU in glycerol solutions with increasing RIs ranging from 1.3320 to 1.4235.en_US
dcterms.abstractAdditionally, three chitosan (CS) based Cd²⁺ imprinted polymers (CS-Cd²⁺IP) were adopted to accomplish sensitive and selective Cd²⁺ monitoring of SMNS. The coating process involved using CS-Cd²⁺ compounds with thermally attached probes to self-generate CS-Cd²⁺IP with low concentrations of 0.2%, 0.5%, and 1% epichlorohydrin (ECH). The probes demonstrated Cd²⁺ selectively sensing ranges of 0 ppb (parts per billion) to 1 ppb (probe 1), 0.01 ppb to 10 ppb (probe 2), and above 1000 ppb (probe 3) with the limit of detection (LOD) of 0.04 ppb, 0.67 ppb, and 66.67 ppb, respectively. Further validation utilizing probe 2 displayed a linear sensitivity of 0.02773 nm/ppb, along with outstanding reusability and a fast transition time of 20 s for various Cd²⁺ concentrations in its application range. Besides, the insensitivity in the weakly acidic range and the temperature sensitivity of -0.0196 nm/°C were presented as well.en_US
dcterms.abstractSubsequently, we proposed another graphene oxide (GO)-cysteamine (MEA)/CS­-Cd²⁺IP bi-layer functional scheme for enhanced Cd²⁺ sensitivity. Three similar SMNS sensors were created by successively dip-coating GO-MEA and CS-Cd²⁺IP to ensure consistent results. The one with the highest sensitivity was -0.1211 nm/ppb among all sensors regarding cadmium levels (0-10 ppb), and it responded in 90 seconds. The strong recognition ability for Cd²⁺ of this probe was further measured in comparison to other heavy metal ions. Moreover, its response across various pH solutions was examined to reduce sensing errors in real scenarios. Additionally, temperature crosstalk was mitigated by evaluating the response of a fiber Bragg grating (FBG).en_US
dcterms.extentx, 70 pages : color illustrationsen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2025en_US
dcterms.educationalLevelM.Sc.en_US
dcterms.educationalLevelAll Masteren_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
8319.pdfFor All Users (off-campus access for PolyU Staff & Students only)3.98 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/13911