Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor | Department of Health Technology and Informatics | en_US |
| dc.contributor.advisor | Cai, Jing (HTI) | en_US |
| dc.creator | Wu, Yuyao | - |
| dc.identifier.uri | https://theses.lib.polyu.edu.hk/handle/200/14600 | - |
| dc.language | English | en_US |
| dc.publisher | Hong Kong Polytechnic University | en_US |
| dc.rights | All rights reserved | en_US |
| dc.title | Evaluation of the pulmonary perfusion generated by deep learning-based enhanced CBCT | en_US |
| dcterms.abstract | Introduction: | en_US |
| dcterms.abstract | With the emerging Cone Beam Computed Tomography (CBCT) enhancement technology, the image quality of CBCT can be improved to a level comparable to Computed Tomography (CT), making it a potential alternative to CT for assessing pulmonary lung function in functional lung avoidance radiotherapy (FLART). However, research on CBCT-based functional image translation is limited, with most studies focusing on translating 4D CBCT to ventilation images. This study aims to evaluate perfusion images generated by enhanced CBCT, quantify their correlation with CT-based perfusion images, and analyze the factors that may affect their clinical application. | en_US |
| dcterms.abstract | Methods: | en_US |
| dcterms.abstract | In this project, thirty lung cancer patients with CBCT-CT pairs and Single-Photon Emission Computed Tomography (SPECT) perfusion images were studied. A previously developed Cycle GAN CBCT enhancement model and a 3D CNN CT-to-perfusion model were utilized to generate perfusion images. Both CBCT images and SPECT perfusion images were registered to the corresponding CT images for further process. Registered CBCT images were input into the Cycle GAN model to produce enhanced CBCT (eCBCT) images. Subsequently, the lung mask generated from CBCT was applied to CBCT, eCBCT, CT, and SPECT images, generating CBCTsegCBCT, eCBCTsegCBCT, CTsegCBCT, and SPECTsegCBCT. Additionally, the CT lung mask was applied to CT and SPECT images for comparison, resulting in CTsegCT and SPECTsegCT. Then all 4 sets of CT images (CBCTsegCBCT, eCBCTsegCBCT, CTsegCBCT, CTsegCT) were translated into perfusion images using the 3D CNN network. Evaluation metrics, including Spearman's correlation coefficient R and structural similarity index measure (SSIM) for voxel-wise agreement and dice similarity coefficient (DSC) for function-wise agreement, were calculated between the generated perfusion images and their corresponding ground truth SPECT images. | en_US |
| dcterms.abstract | Results: | en_US |
| dcterms.abstract | After enhancement, the SSIM between CBCT and CT has increased from 0.804±0.072 to 0.824±0.068, while the PSNR increased from 24.16±2.82 to 25.04±2.88. Furthermore, the MAE decreased from 47.75±15.95 to 40.13±14.61, showing that the eCBCT has higher voxel-wise agreement with CBCT. For CT-to-perfusion translation, the average Spearman correlation R for CBCTsegCBCT, eCBCTsegCBCT, and CTsegCBCT, and CTsegCT were 0.64, 0.68, 0.73, 0.76, and the average SSIM were 0.62, 0.78, 0.76, 0.79, respectively. Function-wise evaluation of generated perfusion images showed a moderate agreement with the ground truth and the 4 sets had similar results, with DSC (High function) around 0.62 and DSC (Low function) around 0.69. In general, the order of performance from best to worse is: CTsegCT, CTsegCBCT, eCBCTsegCBCT, and CBCTsegCBCT, as expected. | en_US |
| dcterms.abstract | Conclusion: | en_US |
| dcterms.abstract | In this study, pulmonary perfusion images were generated from CBCT images, demonstrated the potential application of CBCT-based functional images in FLART. Although reducing noise and artifacts in CBCT images can enhance the accuracy of CT-to-perfusion translation and produce perfusion images with a roughly similar pattern, the incomplete lung regions in CBCT, due to limited fields of view, affect the performance of the CT-based translation model. | en_US |
| dcterms.extent | vi, 42 pages : color illustrations | en_US |
| dcterms.isPartOf | PolyU Electronic Theses | en_US |
| dcterms.issued | 2026 | en_US |
| dcterms.educationalLevel | M.Phil. | en_US |
| dcterms.educationalLevel | All Master | en_US |
| dcterms.accessRights | open access | en_US |
Copyright Undertaking
As a bona fide Library user, I declare that:
- I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
- I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
- I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.
By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.
Please use this identifier to cite or link to this item:
https://theses.lib.polyu.edu.hk/handle/200/14600

