dc.titleApplication of the symbolic and numerical computing programme Mathematica for simulating compartmental firesen_US
dcterms.abstractA thorough study on the application of the symbolic computing techniques to solve mathematical problems involved in simulating compartmental fires was reported. Literature survey on selected symbolic programmes and their application in engineering were also accomplished. A general review on compartmental fires was carried out. MATHEMATICA, one of the general-purpose symbolic computing software packages, was used as an example to perform the study. Comparisons of numerical solutions by MATHEMATICA with exact solutions for eleven ordinary differential equations including one 'stiff' type were performed. Results of which show that MATHEMATICA solutions were only deviated by less than 0.05% from the exact solutions. These findings clearly demonstrate that MATHEMATICA can give very good solutions to various types of differential equations. CHOWMOK-1, a zone fire model developed from MATHEMATICA based on the model ASET, was applied for predicting the smoke layer interface height and the average smoke temperature within a single compartment. Results predicted by CHOWMOK-1 were compared with those by ASET-BX (a simplified version of ASET) for five sets of steady burning fires of heat release rate of 200kw, 300kw, 500kw, 1,000kw and 1,320kW; and two sets of unsteady fires of heat release rate increased by 1 kWs-1 and 2 kWs-1. It is observed that results by CHOWMOK-1 were consistent with those from ASET-BX. Therefore, CHOWMOK-1 is considered to be acceptable as a reference for fire engineering design. Limitations and deficiencies of CHOWMOK-1 have also been explored and discussed in details. Recommendations of how to overcome the limitations and deficiencies have been discussed. Suggestions for future development of CHOWMOK-1 have also been highlighted.en_US
dcterms.extentx, 90, [88] leaves : ill. ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued1998en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Sc.en_US
dcterms.LCSHFires -- Mathematical modelsen_US
dcterms.LCSHMathematica (Computer file)en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b14212511.pdfFor All Users (off-campus access for PolyU Staff & Students only)3.74 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/1989