Full metadata record
DC FieldValueLanguage
dc.contributorMulti-disciplinary Studiesen_US
dc.contributorDepartment of Civil and Structural Engineeringen_US
dc.creatorCheung, Kwok-yu-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/2164-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic University-
dc.rightsAll rights reserveden_US
dc.titleReview of unit generation rates for wastewater flows and loadsen_US
dcterms.abstractIn designing the capacity of a sewerage system, it is important to quantify the wastewater arising within the area where the sewerage system is to serve. In cases where the actual flows and loads are not known, particularly for future scenarios, it is quite common to derive calculated flows and loads. Flows and loads from domestic sources are usually calculated by taking the population figures for the area and multiplying them by the "per capita" daily generation rates. Where the wastewater is generated from an industrial area a "per capita" or "per hectare" flow is often assumed. The DSD Sewerage Manual (May 1995) is considered as one of the most updated sources of reference for deriving calculated flows and loads of domestic and trade effluent in Hong Kong. The unit load generation factors for domestic activities in the Sewerage Manual have taken into account the diurnal variation in transient population, particularly those working, or studying outside their home catchment. It had been assumed that a student or a "economically active" person would only discharge about 50% of their pollution load at home. The remaining portion would be discharged away from home at school or at work. Thus, the domestic load factors were separately derived for residential population and transient population. Based on the ratio of residential to transient population in 1989, the residential factors in the Sewerage Manual were adjusted to be 20% greater than the transient factor, as they are influenced by home makers and retired or unemployed people, who spend more than 50% of their waking hours at home. The acceptability of using these domestic factors was justified under this study by using the year 1997 population data. The results showed that these load factors are acceptable for use to quantify the pollution loads for existing situation. However, for estimation of future domestic loading, it is recommended to conduct the same justification exercise as carried out for this study and make necessary adjustments to the domestic load factors in the Sewerage Manual. On the other hand, the load factors for trade effluent provided in the Sewerage Manual might over-estimate the actual pollution load discharged from industrial and commercial premises for future scenarios. The reason is that these load factors were derived in 1989 for pollution at source. In calculating the actual loads received downstream of industrial and commercial areas in the future, allowance should now be made for the amount of wastewater pre-treatment facilities which is operating inside individual industrial and commercial premises. Based on the findings mentioned above, an improved model was developed in this study to quantify the pollution load generated in a sewerage catchment. A spreadsheet was also created to calculate the running cost for collection, treatment and disposal of wastewater discharged from a sewerage catchment. This spreadsheet was developed by linking the unit generation factors in the DSD Sewerage Manual to the Sewage Charge and Trade Effluent Surcharge rates recently derived by the government for the "Polluter Pays" Scheme.en_US
dcterms.extentvi, 60 leaves ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued1999en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Sc.en_US
dcterms.LCSHSewage disposal -- China -- Hong Kongen_US
dcterms.LCSHSewage -- Environmental aspects -- China -- Hong Kongen_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b14800299.pdfFor All Users (off-campus access for PolyU Staff & Students only)2.94 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/2164