Full metadata record
DC FieldValueLanguage
dc.contributorMulti-disciplinary Studiesen_US
dc.contributorDepartment of Mechanical Engineeringen_US
dc.creatorChiu, Yat-hon-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/2686-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic University-
dc.rightsAll rights reserveden_US
dc.titleComputational analysis of effectiveness of stratified cooling in air-conditioningen_US
dcterms.abstractThis study is to construct a mathematical model that integrates the existing principles in the field of heat transfer and to apply these available theories to predicting the stratified cooling process in air-conditioning. The model treats the air-conditioned enclosure as a coupled air-wall-floor-roof system in which thermal energy is conserved. The steady-state heat convection in the space air is represented by a set of two-dimensional finite difference numerical equations governing the conservation of mass, momentum, and energy. To simulate the stratified cooling effect, this study features the evaluation of boundary conditions by means of empirical correlations and the inclusion of varying air properties with respect to local temperatures. The simulated results are applied to the field measurements done by other academic to demonstrate the validity of the model and program algorithms. Following the same parameters as set up in the field tests, the simulated air temperature gradients are in most cases follow comparatively the patterns of the field measurements. The computer results give a good agreement that the point of transition between the upper and lower zones is determined in the level at which the supply air is introduced. Based on the effect of thermal stratification, the supply air height is then varied to evaluate the cooling load reduction with respect to the supply air level. The computer results show that cooling load reduction of 11% is achieved when the supply air is introduced in the middle level rather than ceiling level based on the conditions of a particular test. However the simulated load calculations are often higher than the field measurements, and a 12% increase in load estimation is resulted. The simulated temperature gradients are in general within the range of up to 4 C deviation when compared to the field measurements.en_US
dcterms.extentxi, 116, [49] leaves : ill. ; 31 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2000en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Sc.en_US
dcterms.LCSHAir conditioningen_US
dcterms.LCSHCoolingen_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b1532171x.pdfFor All Users (off-campus access for PolyU Staff & Students only)4.99 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/2686