dc.titleDemand controlled ventilation for improving energy and environmental performanceen_US
dcterms.abstractSupply CO2-based demand controlled ventilation (S-CO2-DCV) strategy maintains the supply CO2 concentration at a set-point. This strategy is usually applied to the multiple spaces subject to variable occupancy. It settles the set-point considering the full occupancy in the critical zone, Indoor air quality (IAQ) requirement can be satisfied for all the spaces, but extra energy consumption always exists in this control system due to over-ventilation in non-critical zones. In order to improve the energy and environmental performance of this strategy, the optimized set-point control is studied and improved. The improved strategy which called supply CO2 concentration optimized set-point control strategy is presented in this dissertation. This study uses the simulation program which is called Transient System Simulation Program (TRNSYS) to evaluate energy and environmental performance of the improved strategy. The component models required for simulation calculations, such as the building, air handling unit, VAV terminals, sensor, fan, damper, valve, and local and supervisory control loops, are developed and validated against the monitored data. The supply CO2 concentration set-point of the improved strategy could be determined by the monitored zone air flow rates and monitored zone CO2 concentration. It is tested and evaluated by making comparisons with other strategies. Test results indicate that the IAQ and energy consumption are significantly affected by supply CO2 concentration set-point. Supply CO2 concentration optimized set-point control strategy can achieve the tradeoff between the IAQ and energy consumption. This is because the improved strategy takes into account building actual occupancy, critical zone ventilation requirement and critical zone variations in different time. The simulation in this study was conducted based on a cloudy summer test condition. Further study can take into consideration other test conditions of different seasons.en_US
dcterms.extentxiv, 116 leaves : ill. (chiefly col.) ; 30 cm.en_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2006en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Eng.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertations.en_US
dcterms.LCSHVentilation.en_US
dcterms.LCSHIndoor air pollution.en_US
dcterms.LCSHEnergy consumption.en_US
dcterms.LCSHEnergy conservation.en_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b19736733.pdfFor All Users (off-campus access for PolyU Staff & Students only)83.72 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/4291