Full metadata record
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineeringen_US
dc.creatorSze, Wing-hong-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/4461-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic University-
dc.rightsAll rights reserveden_US
dc.titleCombining a room air conditioner and a standalone room air dehumidifier for better indoor thermal comfort condition and higher energy efficiencyen_US
dcterms.abstractSince the process of cooling and dehumidification is coupled in room air conditioners (RACs), it is more challenging for the RACs to provide a better indoor thermal environment and be operated at a higher energy efficiency condition, particularly in the subtropical Hong Kong. This dissertation firstly reports on an experimental work in monitoring the indoor thermal condition and the power performances of the air conditioning in a test chamber employing either a RAC or both a RAC and a standalone room dehumidifier (DEHU) under three different operating strategies: the individual use of RAC, the combined use of a RAC and DEHU, as well as the combined use of a RAC and DEHU with an external condenser of the DEHU. This is followed by a report of a simulation study of the indoor thermal conditions and energy performances under the same three operating strategies based on the summer design day and annual basis in subtropical Hong Kong, using a building energy simulation program. The results of the experimental work and simulation study show that, under a hot and humid environment, the combined use of a RAC and DEHU could maintain a relatively lower level of indoor RH than employing a RAC only. Since the use of DEHIJ requires additional energy, this possibly increases the overall energy consumption. However, with the use of a proposed novel with an external condenser, it could not only control the indoor RH level, but could also reduce the overall energy consumption. It would appear that the DEHU with an external condenser plays an important role to effectively control the indoor RH and to enhance the energy performance of space conditioning in residences. Therefore, a novel design for a DEHU with an external condenser has been proposed.en_US
dcterms.extentxi, 115 leaves : ill. ; 30 cm.en_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2006en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Eng.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertations.en_US
dcterms.LCSHAir conditioning.en_US
dcterms.LCSHHumidifiers.en_US
dcterms.LCSHEnergy conservation.en_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b19736769.pdfFor All Users (off-campus access for PolyU Staff & Students only)10.93 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/4461