Full metadata record
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineeringen_US
dc.creatorLau, Siu-kit-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/5316-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic University-
dc.rightsAll rights reserveden_US
dc.titleActive control of sound transmission into enclosure through a panelen_US
dcterms.abstractThe thesis is concerned with the effectiveness of active sound transmission control inside an enclosure under the potential energy, squared pressure and energy density control algorithms using a purely vibration actuator, a purely acoustic source and combined source system. The principal application is to effectively use various control algorithms and sources on the active control of sound transmission into an enclosure and control of its resultant sound fields. The main objective of this thesis is to clarify the role of acoustic and vibration actuators, as well as error sensors and sensing schemes, in the global and local control of harmonic sound transmission into a structural-acoustic coupled system with different strength of structural-acoustic coupling. The effects of the edge rotational and translational flexibility of the flexible structure on the active sound transmission control are investigated in detail. The objective is tackled by way of investigations into i) the physics of structural-acoustic coupled systems and ii) the physical limitation and control mechanisms of active sound transmission control. The investigations were performed by employing three concepts: sound-field visualization for the analysis of active noise control, normalized impedance and mobility for the analysis of structural-acoustic coupled systems, and the effects of the edge rotational and translational flexibility of the flexible structure on the active sound transmission control. Effectiveness of global and local sound field control inside an enclosure under the potential energy, squared pressure and energy density control algorithms were investigated numerically in this thesis. Modal analysis with three-dimensional visualization of the sound field, as well as resultant total acoustic potential energy attenuation, was performed. Significant localized sound attenuation can be achieved in specific areas even with an overall amplification of total acoustic potential energy in the enclosure, showing the limitation of traditional potential energy analysis. The present results also showed the occurrence of the detrimental effects and spillovers under the squared pressure control, while they can be removed by using the energy density control. The spillover effect results from the control source inadvertently exciting higher order modes. The energy density control results in more uniform sound fields and a performance similar to the theoretical solution of potential energy control. However, it is not effective if the error sensor is located near to the secondary sound source. The present finding on producing large quiet zones using a simple system has significant implication for building noise control. The concept of impedance-mobility approach was extended to the energy density based active control in structural-acoustic coupled systems. Formulae based on the normalized impedance-mobility approach were developed for the active sound transmission control with consideration of flexible structures with edges elastically supported against translation and rotation. Full coupling between the flexible structure and the interior acoustic cavity is considered. The criteria of weak coupling were defined in detail. Formulae for the coupled eigen-frequencies of the structural-acoustic coupled systems were also derived. For active sound transmission control, previous work has considered the classical boundary conditions of the flexible structures (i.e. simply supported and clamped edges). The analysis of active sound transmission control in this thesis was extended to the cases where the edges of the panel structure are elastically restrained in rotation and translation. Results showed that effective active control is obtained for pure vibration control at low frequency, but poor performance occurs at low rotational or translational flexibility at high frequency. Pure acoustic control gives a more uniform performance for various combinations of edge rotational and translational flexibilities. Also, effective pure acoustic control can be achieved at some eigen-frequencies of the enclosure, at high frequencies and at some pairs of rotational and translational flexibilities with ineffective transmission of acoustic energy.en_US
dcterms.extentxxxii, 313 p. : ill. ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2003en_US
dcterms.educationalLevelAll Doctorateen_US
dcterms.educationalLevelPh.D.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.LCSHSound -- Transmission -- Measurementen_US
dcterms.LCSHAcoustic modelsen_US
dcterms.LCSHNoise controlen_US
dcterms.accessRightsopen accessen_US

Files in This Item:
File Description SizeFormat 
b16823400.pdfFor All Users20.67 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/5316