dc.title | Evaluating the energy performance of high temperature differential chiller | en_US |
dcterms.abstract | Nowadays people spend more time to stay in the building, it consumes more energy for the air-conditioning system. It is a great potential to saving energy of the air-conditioning system since the energy consumption of the air conditioning system consumption half of the building energy. This study proposes a high temperature differential chiller system to provide air-conditioning in a building. It increases the temperature different of the chilled water supply and return temperature from 5°C to 9°C. The Primary Air handle unit (PAU) treats all the latent and part of sensible load of the building while the dry fan coil unit handles the sensible load from the room only. It can prevent the condensation occur in the room, it can provide a better indoor air quality. To evaluate the energy performance of the high temperature differential chiller system, simulation software energyplus is employed in this study. It can simulate the energy performance of the system, and investigate the room condition at the same time. Compared with conventional system, the energy saving of the high temperature differential chiller system can reach 9%, and it can provide a more comfortable and health environment to the occupants. | en_US |
dcterms.extent | [ix], 70 leaves : ill. ; 31 cm. | en_US |
dcterms.isPartOf | PolyU Electronic Theses | en_US |
dcterms.issued | 2010 | en_US |
dcterms.educationalLevel | All Master | en_US |
dcterms.educationalLevel | M.Eng. | en_US |
dcterms.LCSH | Hong Kong Polytechnic University -- Dissertations | en_US |
dcterms.LCSH | Air conditioning -- Energy consumption | en_US |
dcterms.LCSH | Temperature measurements | en_US |
dcterms.accessRights | restricted access | en_US |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
b23563783.pdf | For All Users (off-campus access for PolyU Staff & Students only) | 6.85 MB | Adobe PDF | View/Open |
Copyright Undertaking
As a bona fide Library user, I declare that:
- I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
- I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
- I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.
By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.
Please use this identifier to cite or link to this item:
https://theses.lib.polyu.edu.hk/handle/200/5751