Full metadata record
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineeringen_US
dc.creatorZhu, Na-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/6191-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic University-
dc.rightsAll rights reserveden_US
dc.titleEnergy performance and optimal control of air-conditioned buildings integrated with phase change materialsen_US
dcterms.abstractThermal energy storage (TES) systems using phase change materials (PCMs) have been recognized as one of the advanced energy technologies in enhancing energy efficiency and sustainability of buildings. The use of PCMs in buildings provides the potential for a better indoor thermal comfort for occupants due to the reduced indoor temperature fluctuations, and lower overall energy consumption due to the load reduction/shifting. This thesis presents an overview of the previous research work on dynamic characteristics and energy performance of buildings due to the integration of PCMs. The research work on dynamic characteristics and energy performance of buildings using PCMs both with and without air-conditioning is reviewed. Since the particular interest in using PCMs for free cooling and peak load shifting, specific research efforts on both subjects are reviewed separately. The use of phase change materials (PCMs) to enhance the building energy performance has attracted increasing attention of researchers and practitioners over the last few years. Thermodynamic models of building structures using PCMs are essential for analyzing their impacts on building energy performance at different conditions and using different control strategies. There are few PCM models of detailed physics providing good accuracy in simulating thermodynamic behavior of building structures integrated with PCM layers. However, simplified models with acceptable accuracy and good reliability are preferable in many practical applications concerning computation speed and program size particularly when involving large buildings or models are used for online applications. A simplified physical dynamic model of building structures integrated with SSPCM (shaped-stabilized phase change material) is developed and validated in this study. The simplified physical model represents the wall by 3 resistances and 2 capacitances and the PCM layer by 4 resistances and 2 capacitances respectively while the key issue is the parameter identification of the model. The parameters of the simplified model are identified using genetic algorithm (GA) on the basis of the basic physical properties of the wall and PCM layer. Two GA-based preprocessors are developed to identify the optimal parameters (resistances and capacitances) of the model by frequency-domain regression and time-domain regression respectively. Validation results show that the simplified model can represent light walls and median walls integrated with SSPCM with good accuracy.en_US
dcterms.abstractThis thesis also presents the studies on the thermodynamic characteristics of buildings enhanced by PCM and on the investigation of the impacts of PCM on the building cooling load and peak cooling demand at different climates and seasons as well as the optimal operation and control strategies to reduce the energy consumption and energy cost by reducing the air-conditioning energy consumption and peak load. An office building floor with typical variable air volume (VAV) air-conditioning system is used and simulated as the reference building in the comparison study. The envelopes of the studied building are further enhanced by integrating the PCM layers. The building system is tested in two selected cities of typical climates in China including Hong Kong and Beijing. The cold charge and discharge processes, the operation and control strategies of night ventilation and the air temperature set-point reset strategy for minimizing the energy consumption and electricity cost are studied. This thesis presents the simulation test platform, the test results on the cold storage and discharge processes, the air-conditioning energy consumption and demand reduction potentials in typical air-conditioning seasons in typical China cites as well as the impacts of operation and control strategies.en_US
dcterms.extentxxiii, 191 leaves : ill. ; 30 cm.en_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2011en_US
dcterms.educationalLevelAll Doctorateen_US
dcterms.educationalLevelPh.D.en_US
dcterms.LCSHBuildings -- Energy conservation.en_US
dcterms.LCSHBuildings -- Energy consumption.en_US
dcterms.LCSHPhase transformations (Statistical physics)en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsopen accessen_US

Files in This Item:
File Description SizeFormat 
b24562099.pdfFor All Users2.22 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/6191