dcterms.abstract | This paper discusses on the results of a real fire test on newly cast R.C. structural members, plain concrete members, an existing R.C. structure and structural steel members with different damage mitigation measures and protection treatments. A real fire test was conducted on 20.8.2010 in an existing one-storey R.C. pump house which was converted into a fire chamber comprising two sub-chambers for testing reinforced concrete and plain concrete columns. The temperature of those columns and the air inside the two sub-chambers was fully monitored during the fire test, by thermocouples. Different damage mitigation measures and protection treatments were applied to the concrete columns, existing R.C. structural members and structural steel members. Water quenching to the columns was carried out in one sub-chamber. A number of tests were carried out to the tested columns, existing R.C. structural members and structural steel members to quantify the fire damages. Records of temperature and observed damages were also analyzed together with those test results. Based on the analyses of the test results, recorded temperature and observed damage, performance of different damage mitigation measures and protection treatment was compared. The observed difference in damage between R.C. structural members and plain concrete members were analyzed. The effect of water quenching was studied. The damage of structural steel members was analyzed. A methodology on investigation of R.C. structures after fire was suggested and verified in a real fire case. All those findings in the analyses as mentioned above were presented in this report. | en_US |
dcterms.extent | xviii, 170 p. : ill. (chiefly col.) ; 30 cm. | en_US |
dcterms.isPartOf | PolyU Electronic Theses | en_US |
dcterms.issued | 2013 | en_US |
dcterms.educationalLevel | All Master | en_US |
dcterms.educationalLevel | M.Sc. | en_US |
dcterms.LCSH | Reinforced concrete construction -- Fire testing. | en_US |
dcterms.LCSH | Concrete -- Fire testing. | en_US |
dcterms.LCSH | Building, Iron and steel -- Fires and fire prevention. | en_US |
dcterms.LCSH | Hong Kong Polytechnic University -- Dissertations | en_US |
dcterms.accessRights | restricted access | en_US |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
b26271011.pdf | For All Users (off-campus access for PolyU Staff & Students only) | 17.02 MB | Adobe PDF | View/Open |
Copyright Undertaking
As a bona fide Library user, I declare that:
- I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
- I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
- I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.
By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.
Please use this identifier to cite or link to this item:
https://theses.lib.polyu.edu.hk/handle/200/7047