Full metadata record
DC FieldValueLanguage
dc.contributorInterdisciplinary Division of Biomedical Engineeringen_US
dc.creatorLiu, Peng-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/7553-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic University-
dc.rightsAll rights reserveden_US
dc.titleOptimization of imaging system for micro-ultrasounden_US
dcterms.abstractHigh-frequency micro-ultrasound, also known as ultrasound bio-microscopy, has the capability to show living tissue structures in detail with resolution on the order of tens of microns. With the help of imaging contrast agent, the sensitivity and resolution could be even higher. Mirco-ultrasound is a powerful imaging tool in biological and preclinical researches. In clinic, it is also used extensively in the diagnosis of cardiovascular, dermatology, ophthalmology and cartilage disease. This study was based on an existing micro-ultrasound imaging system, which was composed of a pulse generator and a signal receiver. After preparing and testing the basic function, a new non-isolated DC power supply was proposed. It was able to convert +12V DC input into ±50V DC output to provide steady power supply for the pulse generator. The maximum output current was up to 150mA, and the maximum output power was 12W. The output voltage could be configured through SPI interface, ranging from ±3V to ±90V to accommodate with different transducers and various application situations. To realize Doppler imaging function, a flexible pulse-wave generation module was designed and implanted in the imaging system. The pulse width and pulse repetition frequency were configurable. Simulation and tests showed that the logic function was correct and the FPGA on-chip resources consumed was acceptable. In addition, data processing flow of Doppler imaging was proposed for system integrity.en_US
dcterms.extent53 leaves : illustrations ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2014en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Sc.en_US
dcterms.LCSHUltrasonic imaging.en_US
dcterms.LCSHImaging systems.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b27577387.pdfFor All Users (off-campus access for PolyU Staff & Students only)2.61 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/7553