dc.title | Analysis of long-term monitoring data obtained by an optical fiber sensory system deployed on Dongjiang water mains | en_US |
dcterms.abstract | A fibre Bragg grating (FBG) sensing network for monitoring the structural integrity of the Dongjiang water mains (DJWM) was developed by The Hong Kong Polytechnic University in conjunction with the Water Supplies Department of Hong Kong SAR Government. The structural integrity of a segment of 200-meter-long glass-reinforced-plastic (GRP) pipes of the water mains has been monitored in terms of strain, temperature, and flow pressure for about one year. A database has been established for statistically analysing the structural performance of the GRP pipes under different conditions. This paper is devoted to the statistical analysis of the monitoring data with the expectation to recognize the performance patterns of the GRP pipes. Firstly, the correlations of the data acquired by sensors deployed at different locations along the pipes are investigated for two purposes: 1) to examine the spatial relationship between different measurement points, and 2) to recognize key positions/cross-sections along the GRP pipeline. Secondly, the time histories of the measured strain, temperature and pressure at key cross-sections are analysed, and some irregularities are identified during the analysis and listed in this paper. Finally, the correlations between measured parameters acquired at the key positions/cross-sections are analysed over a long time period to obtain the temporal performance pattern. If the performance curves about the GRP pipes in later days are not coincident with the formulated patterns after excluding environmental influential factors, anomaly in either sensor or structural integrity is alarmed, and further inspection action is made to identify potential structural defect. | en_US |
dcterms.extent | viii, 62 leaves : illustrations ; 30 cm | en_US |
dcterms.isPartOf | PolyU Electronic Theses | en_US |
dcterms.issued | 2014 | en_US |
dcterms.educationalLevel | All Master | en_US |
dcterms.educationalLevel | M.Sc. | en_US |
dcterms.LCSH | Optical fiber detectors. | en_US |
dcterms.LCSH | Structural stability. | en_US |
dcterms.LCSH | Pipe. | en_US |
dcterms.LCSH | Hong Kong Polytechnic University -- Dissertations | en_US |
dcterms.accessRights | restricted access | en_US |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
b27592273.pdf | For All Users (off-campus access for PolyU Staff & Students only) | 3.52 MB | Adobe PDF | View/Open |
Copyright Undertaking
As a bona fide Library user, I declare that:
- I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
- I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
- I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.
By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.
Please use this identifier to cite or link to this item:
https://theses.lib.polyu.edu.hk/handle/200/7614