dc.titleA modeling investigation of the impact of building openings and podium configurations on personal air pollutant exposure in isolated deep urban canyonsen_US
dcterms.abstractIn this study, the effectiveness of different configurations for two building design elements, building openings and podium configuration, proposed for mitigating or diluting air pollution problems in isolated deep canyons were evaluated using an indirect exposure approach. The indirect approach predicted the exposures of an individual by multiplying the pollutant concentrations with the duration of exposure within a specific micro-environment. In this study, a computational fluid dynamics model was applied to simulate and predict the pollutant concentrations for different building configurations. Based on the Reynolds-Averaged Navier-Stokes (RANS) equations, the computational model was constructed with the standard κ-ε turbulence model. Eighty-four canyon configurations having different building opening areas and heights or podium configurations were examined for aspect ratios of 2, 3, and 4. The findings indicated that pedestrian personal exposures were extremely high if they stayed in a canyon without any building openings or podium when the prevailing wind was perpendicular to the street axis. Building openings were shown to be an effective means to improve in-canyon air circulation and dilute the air pollutant concentration to a reasonable value under perpendicular wind despite their effectiveness being varied with type of configurations i.e. the ratio of the opening area to the area of the wall. Increasing the permeability value through increasing the opening areas from 0 to 10% significantly lowered the mean and maximum personal exposures at pedestrian level. And the highest effectiveness was achieved when the height of the opening was 5m from the ground level. Likewise, the personal exposures could also be reduced by the introduction of building podium whose effectiveness was not influenced by canyon aspect ratios as strongly as other building configurations. These findings provide valuable insights for urban planners.en_US
dcterms.extent46 leaves : color illustrations ; 30 cmen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2014en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Sc.en_US
dcterms.LCSHBuildings -- Environmental engineering.en_US
dcterms.LCSHAir -- Pollutionen_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b27606284.pdfFor All Users (off-campus access for PolyU Staff & Students only)1.31 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/7650