dc.titleA simulation study on reducing total nighttime cooling load in a subtropical bedroom by applying phase change material (PCM)/vacuum insulation panel (VIP) coupling system in the building envelopesen_US
dcterms.abstractIn the subtropical regions, air conditioning (A/C) for a bedroom in residential buildings commonly served to provide an appropriate indoor thermal environment at nighttime for sleeping during daytime when A/C was not provided, a large amount of thermal energy can be stored in the thermal mass in its envelope components, in particularly its external walls. The energy stored would be gradually released, contributing significantly to the total space cooling load in the bedroom at nighttime. Therefore, this dissertation takes a simulation study on further analysing the nighttime cooling load characteristics in a hypothetic west-facing bedroom in subtropical Hong Kong and on the effects of adding VIP (vacuum insulation panel) and PCM (phase change material) coupling system to the west-facing external wall in the bedroom on reducing the thermal energy stored in the wall and consequently the nighttime cooling load. The application of VIP/PCM coupling system in the building envelop can significantly reduce the total cooling load from the building envelope, and a reduction of 45.27% has obtained. Besides the effect on cooling load, the variation of the indoor temperature is also reduced. The software EnergyPlus is introduced to as the simulation tool. In order to optimize material selection, the following experiments have taken to discuss the effects of the properties of the materials, such as melting temperature, thickness. Besides that, the thesis attempts to explain the reasons for the drop of total cooling load.en_US
dcterms.extent65 pages : color illustrationsen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2016en_US
dcterms.educationalLevelAll Masteren_US
dcterms.educationalLevelM.Eng.en_US
dcterms.LCSHAir conditioning -- Efficiency.en_US
dcterms.LCSHCooling load -- Measurement.en_US
dcterms.LCSHBuildings -- Environmental aspects.en_US
dcterms.LCSHBuildings -- Energy conservation.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
b2917143x.pdfFor All Users (off-campus access for PolyU Staff & Students only)2.12 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/8623