Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor | Multi-disciplinary Studies | en_US |
dc.contributor | Jockey Club Rehabilitation Engineering Centre | en_US |
dc.creator | Li, Ming-wah | - |
dc.identifier.uri | https://theses.lib.polyu.edu.hk/handle/200/881 | - |
dc.language | English | en_US |
dc.publisher | Hong Kong Polytechnic University | - |
dc.rights | All rights reserved | en_US |
dc.title | Effects of prosthetic alignment changes on interfacial pressure in anteroposterior translation under level and non-level walking conditions | en_US |
dcterms.abstract | Prosthesis alignment of a trans-tibial prosthesis is defined as the tree-dimensional position and orientation of the socket relative to the prosthetic foot. Clinically, the prosthesis alignment is finalized based on subjective feeling of the amputee and the observed gait pattern. This procedure is subjective and skin breakdown at the interface between residual limb and socket is not uncommon. It is hypothesized that the interfacial stress between the residual limb and the socket could be optimized if an 'optimal' alignment is prescribed. In this study, the effects of prosthesis alignment on the interfacial pressure were investigated using an interfacial pressure mapping system (Tekscan System, USA). Although prosthesis alignment can be varied with 6 degrees-of-freedom, only the effects of antero-posterior (AP) translation of the socket relative to the prosthetic foot were investigated. Prosthesis alignment ranges of 5 subjects with amputation were firstly determined for level and non-level walking condition. Subsequently, interfacial pressures of the subjects walking with various alignments within the alignment range were measured and compared. The results showed that pressures varied between each subject and measurement sites in two walking condition. Hence, optimal alignment acceptable in level walking may not be acceptable in non-level walking and optimal alignment may not be prescribed at a low interfacial pressure situation. It was also found that the non-level walking was the most sensitive to prosthesis alignment change. Numerous other parameters are recommended for further study, as optimal alignment is compromise of various parameters. | en_US |
dcterms.extent | ix, 131 leaves : ill. ; 30 cm | en_US |
dcterms.isPartOf | PolyU Electronic Theses | en_US |
dcterms.issued | 2001 | en_US |
dcterms.educationalLevel | All Master | en_US |
dcterms.educationalLevel | M.Sc. | en_US |
dcterms.LCSH | Hong Kong Polytechnic University -- Dissertations | en_US |
dcterms.LCSH | Prosthesis | en_US |
dcterms.LCSH | Artificial limbs | en_US |
dcterms.accessRights | restricted access | en_US |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
b16277533.pdf | For All Users (off-campus access for PolyU Staff & Students only) | 3.89 MB | Adobe PDF | View/Open |
Copyright Undertaking
As a bona fide Library user, I declare that:
- I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
- I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
- I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.
By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.
Please use this identifier to cite or link to this item:
https://theses.lib.polyu.edu.hk/handle/200/881