dc.titleData center technology and managementen_US
dcterms.abstractThis dissertation provides the readers a knowledge of Data Centers with strategic planning, design, technologies, and disaster recovery and business continuity. Furthermore, it involves the current best practices for operating and managing a Data Center efficiently and effectively. This dissertation is designed to cover following 7 chapters. In Chapter 1, it provides some key elements in planning and design Data Centers. It consists of Data Center definition, vision, roadmap and strategic planning and global location planning. In Chapter 2, there is an overview of the cabinet, server rack, network, and large frame platform respectively. Besides, it explains the requirements for the design of computer room with coordination of HVAC system, power distribution, fire detection, protection system, and lighting. Furthermore, it will address the modular design and space planning. In Chapter 3, it describes the fundamentals of virtualization, cloud, SDN, and SDDC respectively. There are some benefits and challenges of the technologies to Data Center practitioners. Green Microprocessor and Server Design focus on how to judge and select them as the best fit to sustainable Data Centers. Besides, there are some principles to help the selection of network devices and servers. In Chapter 4, it introduces the background of the network technology. Then, the fundamentals of networking protocol (OSPF, BGP, and MPLS), would be discussed. Besides, the technology of Traffic Engineering (TE) would be explained. In Chapter 5, Data Center Infrastructure Management (DCIM) will be introduced. It is about the convergence of IT and building facilities functions in a Data Center. The objective of a DCIM approach is to provide administrators with a complete view of the utilization. In Chapter 6, there is a case study of the Great East Japan Earthquake. Natural disasters to the physical infrastructure could be devastating many Data Centers like tsunami and earthquake. Therefore, it is vital to obtain a strategy for disaster recovery (DR) and business continuity (BC). We will be prepared well for the inevitable if we learn more from past experience and augment BC and DR. In Chapter 7, the future of Data Center would be the topic. Data centers were considered the reliability preference rather than energy efficiency. In recent years, as they consumed a vast amount of energy, they are gaining social interest for energy policy regulations of the government. As a result, the effort is going to increase the energy efficiency in various perspectives.en_US
dcterms.extentxii, 152 pages : color illustrationsen_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2017en_US
dcterms.educationalLevelM.Sc.en_US
dcterms.educationalLevelAll Masteren_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.LCSHData processing service centers -- Managementen_US
dcterms.LCSHDatabase managementen_US
dcterms.accessRightsrestricted accessen_US

Files in This Item:
File Description SizeFormat 
991021953151003411.pdfFor All Users (off-campus access for PolyU Staff & Students only)3.47 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/9009