dc.titleA critical study on the fire safety for big hotels in Hong Kongen_US
dcterms.abstractFire safety is always a major concern in hotel operations and guest services. A critical study on the fire safety in big hotels in Hong Kong was carried out in this thesis. A detailed review on all the fire safety codes and requirements relating to hotel accommodation was carried out. Local codes on the fire services installations (FSI) required issued by the Fire Services Department were reviewed and the codes from the Buildings Department were studied. Hotel licensing requirements by the local Home Affairs Department were introduced. Fire safety requirements in the Mainland China code on high-rise buildings, the National Fire Protection Association safety code and other fire safety guidelines in USA were also discussed. The total fire safety concept was found to be very important to hotel staff and guests. On the hardware side, the active fire protection systems commonly adopted by firemen in fire fighting against fires in hotel were examined and analyzed critically. These systems are also essential to the fire fighting team of the hotel itself. Another hardware component, the passive fire protection systems including fire resisting constructions, means of escape and areas of access were studied. To most of the hotel operations, the software component, namely a proper fire safety management scheme, is often regarded as more important in international chain hotels. Housekeeping and maintenance of the passive protection installations play a major role in the overall fire fighting strategy. A critical hazard area in the hotel, i.e. the kitchen, was then focused on. Safety concerns and problems usually encountered in kitchens were surveyed and analyzed. Full-scale burning tests in part of a sample kitchen were performed. Fire scenarios and the action of active fire systems such as sprinkler and water mist systems were assessed. In addition to the heat release rate, maximum temperature and fire extinction time were examined and analyzed. It was found that the temperature could reach the flashover temperature of 600 C in some cases, and the heat release rate could be as high as 1.4 MW. No splashing or spilling of fuel was found for the test arrangements in the model kitchen. The sprinkler and water mist system were shown to be effective in extinguishing kitchen fires but less extinguishing time was required in using the sprinkler system. These experimental results provide valuable guidelines for the design of fire safety provisions in hotel kitchens. This refers not only to hardware fire safety systems, but also software fire safety management to achieve total fire safety. Experimental studies were carried out for studying thermal sensitivity of fusible links at fire dampers normally installed in hotel guestrooms. Two groups of experiments were carried out to examine the thermal response of fusible links with a heated wind tunnel. The first group of experiments involved testing 50 fusible links following common standards used in the USA, i.e., Underwriters' Laboratories 33 on heat responsive links at constant temperature and air speed. All the fusible links fulfilled the operating time as recommended. The second group of experiments involved the testing of fusible links at various temperatures and air speeds. Recording the operating time of the fusible links would give the response time index by plotting a suitable graph.en_US
dcterms.extentxiv, 155, [62] leaves : ill. ; 31 cm.en_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2007en_US
dcterms.educationalLevelAll Doctorateen_US
dcterms.educationalLevelPh.D.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertations.en_US
dcterms.LCSHHotels -- China -- Hong Kong -- Fires and fire prevention.en_US
dcterms.accessRightsopen accessen_US

Files in This Item:
File Description SizeFormat 
b20940488.pdfFor All Users2.05 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/965