Author: Lee, Tat-hing Louis
Title: Design and implementation of a wireless A-mode PDA-based ultrasound measurement device
Degree: M.Sc.
Year: 2007
Subject: Hong Kong Polytechnic University -- Dissertations.
Ultrasonic imaging.
Palm (Computer) -- Medical applications.
Department: Department of Health Technology and Informatics
Pages: vii, 85 leaves : ill. ; 30 cm.
Language: English
Abstract: Ultrasound diagnostic scanning has commonly been used for early detection of fetal abnormalities. Both patients and physicians enjoy the advantages of non-invasive diagnosis methods. It is believed that if the size of the scanning machine is less bulky and more portable and if it can maintain the accuracy in collecting the diagnostic data, its efficiency, flexibility and accuracy of measurement can be improved. Therefore, in this project, an A-mode wireless ultrasound probe was designed and a Palm was used for the backend processing. The aim is to develop an A-mode ultrasonic probe and merge wireless to a Palm device together to form an easy-to-use handheld scanner for the measurement of thickness and stiffness of tissues. Regarding the wireless ultrasound probe, a PIC MCU was used in the probe and the EmbeddedBlue TM eb500 was for the Bluetooth UART which helped transfer data to the Palm. A password was needed to enter before connecting the Bluetooth modules and the Palm, which prevented the data from disclosing to unauthorized persons. The collected data can be saved inside the Palm for future use. The file was in PDB format and it could be recognized by any Palm device. The program can run not only in Palm T5 but also in Palm TX PDA. After the construction of the prototype, some experiments were conducted on phantoms to test the device performance. The ultrasound and force information were recorded during the experiment for future use. The thickness and the elasticity of the specimen were calculated. The results demonstrated that the current system was capable of handling the A-mode operation. To the best of our knowledge, this is the first study to use PDA and Bluetooth link for constructing an ultrasound measurement device. Future studies should be conducted to further improve the device by increasing the ultrasound frame rate, improving the user-interface, and adding more functions.
Rights: All rights reserved
Access: restricted access

Files in This Item:
File Description SizeFormat 
b22765803.pdfFor All Users (off-campus access for PolyU Staff & Students only)2.68 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show full item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/3465