Full metadata record
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineeringen_US
dc.creatorSun, Yongjun-
dc.identifier.urihttps://theses.lib.polyu.edu.hk/handle/200/5483-
dc.languageEnglishen_US
dc.publisherHong Kong Polytechnic University-
dc.rightsAll rights reserveden_US
dc.titleOnline optimal control of multiple-chiller systems in large buildingsen_US
dcterms.abstractThis thesis investigates the online optimal control of multiple-chiller systems in large buildings with enhanced robustness and cost efficiency. The control mainly includes chiller sequencing control, optimal start control and electrical demand limiting control. New strategies in the three subjects are proposed and validated on a dynamic simulation platform as well as using site data. In the first subject, i.e. chiller sequencing control, three methods are developed to enhance its robustness and reliability. Firstly, the data fusion method is proposed to obtain a more accurate and reliable cooling load measurements by combining the complementary advantages of two different load measurements. Secondly, a simplified model is developed to online compute the varying maximum cooling capacity of individual chiller. Thirdly, an online sensor fault detection and diagnosis (FDD) strategy is developed to ensure that the sensors used in the direct measurement III work healthily. In the optimal start control, a model-based strategy is proposed for minimizing the energy consumption of the central chilling plant in the morning start period. The model-based strategy is realized in two steps. The first step is to identify a feasible set for the operating chiller number. The second step is to estimate the pre-cooling lead time using the simplified building model for each number inside the feasible range identified, and calculate the corresponding energy consumption. In the subject of electrical peak demand limiting control, a strategy of minimizing the monthly electricity bill is proposed via utilizing the building thermal mass. Previous studies can not to achieve maximized monthly cost saving because the demand cost reduction may be largely/completely traded off by the energy cost rise. Therefore, a strategy taking full consideration of the relationship is developed. The strategy consists of two phases. The first one is to predict a suitable monthly peak demand threshold. In the second phase, the extended pre-cooling lead time will be determined based on the difference between the demand threshold and the predicted daily peak demand. The developed strategies are validated through case studies, which show the satisfactory performances.en_US
dcterms.extentxxviii, 208 leaves : ill. ; 30 cm.en_US
dcterms.isPartOfPolyU Electronic Thesesen_US
dcterms.issued2010en_US
dcterms.educationalLevelAll Doctorateen_US
dcterms.educationalLevelPh.D.en_US
dcterms.LCSHHong Kong Polytechnic University -- Dissertationsen_US
dcterms.LCSHAir conditioning -- Equipment and suppliesen_US
dcterms.LCSHAir conditioning -- Controlen_US
dcterms.LCSHAir conditioning -- Energy consumption.en_US
dcterms.accessRightsopen accessen_US

Files in This Item:
File Description SizeFormat 
b23517268.pdfFor All Users5.13 MBAdobe PDFView/Open


Copyright Undertaking

As a bona fide Library user, I declare that:

  1. I will abide by the rules and legal ordinances governing copyright regarding the use of the Database.
  2. I will use the Database for the purpose of my research or private study only and not for circulation or further reproduction or any other purpose.
  3. I agree to indemnify and hold the University harmless from and against any loss, damage, cost, liability or expenses arising from copyright infringement or unauthorized usage.

By downloading any item(s) listed above, you acknowledge that you have read and understood the copyright undertaking as stated above, and agree to be bound by all of its terms.

Show simple item record

Please use this identifier to cite or link to this item: https://theses.lib.polyu.edu.hk/handle/200/5483